ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it comes to making sure safety in industrial, commercial, and property spaces, slip resistance testing is a vital aspect. At ATTAR (Advanced Technology Testing & Research), we specialize in floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help services and homeowner mitigate risks and adhere to security requirements.
With state-of-the-art equipment such as the pendulum slip test device and moisture meter for concrete, we supply precise and independent slip testing services across Australia. Our knowledge covers ASTM F2170 compliance, R Score evaluations, P Ranking tiles, and more, ensuring your floors satisfy the greatest security standards.
Why Slip Resistance Testing is Essential
Slips and falls are among the leading reasons for office and public injuries. Correct slip testing assists recognize hazardous surfaces before accidents happen. Whether you need wet pendulum test assessments or pendulum test for slip resistance, ATTAR delivers accurate outcomes to improve security.
Secret Services Provided by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Score and P Ranking tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 compliant evaluations.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Guarantees exposure for visually impaired individuals.
- Complies with Australian accessibility standards.
4. On-Site & Laboratory Testing
- Slip test maker for precise on-site examinations.
- Wet pendulum test for damp surface area slip resistance.
Understanding Slip Resistance Rankings: R Ranking vs. P Ranking
When carrying out slip resistance testing, two key classifications are used:.
- R Rating (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, commonly utilized in Europe.
- P Score (Pendulum Test - AS 4586)
Evaluates dynamic friction utilizing a pendulum test slip resistance device, commonly adopted in Australia.
ATTAR supplies independent slip testing to identify whether your flooring fulfills the required pendulum rating tiles requirements.
The Importance of Concrete Moisture Testing
Excess moisture in concrete slabs can cause floor covering failures, mold growth, and adhesive destruction. Our concrete moisture testing services consist of:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to ensure optimum conditions for floor installations.
By spotting moisture concerns early, we assist prevent pricey repairs and make sure lasting flooring efficiency.
Luminance Contrast for Ease Of Access Compliance
Proper luminance contrast is vital for visually impaired people to navigate areas safely. ATTAR examines:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.
Our assessments ensure compliance with Australian Impairment Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where relevant).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Quick & Trustworthy Reporting.
For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, check here Australia.
Phone: +61 1300 139 155.
Typical Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, dining establishments, and offices require safe flooring to prevent client and staff member injuries. Our pendulum slip test ensures compliance with security regulations.
2. Industrial & Warehouse Facilities
High-traffic commercial environments require durable, slip-resistant flooring. ATTAR's slip testing services help keep work environment security.
3. Healthcare & Aged Care Facilities
Hospitals and assisted living home must decrease slip dangers. Our luminance contrast and slip resistance testing ensure safe mobility for clients and staff.
4. Public Facilities
Footpaths, train stations, and federal government structures require independent slip testing to satisfy accessibility and safety requirements.
How ATTAR Conducts Slip Resistance Testing
Step 1: Surface Area Assessment
We assess floor covering products and conditions (dry, wet, or infected).
Step 2: Pendulum Slip Test (AS 4663)
Using a slip test device, we determine the dynamic coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Replicates slippery conditions to examine real-world slip risks.
Step 4: Reporting & Compliance Accreditation
Detailed reports with R Score or P Ranking tiles classifications.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance technique includes a swinging arm with a rubber slider that mimics a foot's movement. The test procedures:.
- Slip Potential Value (SPV).
- Pendulum ranking tiles classification (P0 to P5).
Higher scores (P4/P5) suggest much better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and compliant testing services.
Ensure your residential or commercial property satisfies security requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By choosing ATTAR, you invest in independent slip testing services, pendulum test slip resistance accuracy, and long-term floor safety services. Let us help you produce much safer, compliant, and moisture-resistant environments.
Comments on “Helping The others Realize The Advantages Of Pendulum Test Slip Resistance”